CVE-2020-7480

A CWE-94: Improper Control of Generation of Code (‘Code Injection’) vulnerability exists in Andover Continuum (All versions), which could cause files on the application server filesystem to be viewable when an attacker interferes with an application’s processing of XML data.

CVE-2020-7479

A CWE-306: Missing Authentication for Critical Function vulnerability exists in IGSS (Versions 14 and prior using the service: IGSSupdate), which could allow a local user to execute processes that otherwise require escalation privileges when sending local network commands to the IGSS Update Service.

CVE-2020-5722

The HTTP interface of the Grandstream UCM6200 series is vulnerable to an unauthenticated remote SQL injection via crafted HTTP request. An attacker can use this vulnerability to execute shell commands as root on versions before 1.0.19.20 or inject HTML in password recovery emails in versions before 1.0.20.17.

CVE-2020-7476

A CWE-426: Untrusted Search Path vulnerability exists in ZigBee Installation Kit (Versions prior to 1.0.1), which could cause execution of malicious code when a malicious file is put in the search path.

CVE-2020-7477

A CWE-754: Improper Check for Unusual or Exceptional Conditions vulnerability exists in Quantum Ethernet Network module 140NOE771x1 (Versions 7.0 and prior), Quantum processors with integrated Ethernet – 140CPU65xxxxx (all Versions), and Premium processors with integrated Ethernet (all Versions), which could cause a Denial of Service when sending a specially crafted command over Modbus.

CVE-2020-7478

A CWE-22: Improper Limitation of a Pathname to a Restricted Directory exists in IGSS (Versions 14 and prior using the service: IGSSupdate), which could allow a remote unauthenticated attacker to read arbitrary files from the IGSS server PC on an unrestricted or shared network when the IGSS Update Service is enabled.

CVE-2020-7481

A CWE-79:Improper Neutralization of Input During Web Page Generation (‘Cross-site Scripting’) vulnerability exists Andover Continuum (All versions), which could enable a successful Cross-site Scripting (XSS attack) when using the products’ web server.

CVE-2019-6558

In Auto-Maskin RP210E Versions 3.7 and prior, DCU210E Versions 3.7 and prior and Marine Observer Pro (Android App), the software contains a mechanism for users to recover or change their passwords without knowing the original password, but the mechanism is weak.

CVE-2020-6967

In Rockwell Automation all versions of FactoryTalk Diagnostics software, a subsystem of the FactoryTalk Services Platform, FactoryTalk Diagnostics exposes a .NET Remoting endpoint via RNADiagnosticsSrv.exe at TCPtcp/8082, which can insecurely deserialize untrusted data.